MEV50A200-25G - MEV50A200-25G
Fusible Evpack 500VDC UL 500VDC CEI 200A Taille 25G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Fusible Evpack 500VDC UL 500VDC CEI 200A Taille 25G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Fiche produits
Drawings
pdf - 161.24 Ko
Compliances
pdf - 157.17 Ko
pdf - 211.48 Ko
pdf - 157.1 Ko
Numéro d'article | MEV50A200-25G |
Numéro de catalogue | MEV50A200-25G |
Description | Fusible Evpack 500VDC UL 500VDC CEI 200A Taille 25G Pouvoir de coupure max. DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Boulonné |
Code EAN / UPC | 6972238870219 |
Tension nominale DC UL | 500 V |
Tension nominale DC CEI | 500 V |
Courant assigné | 200 A |
Conforme à ROHS | Oui |
AC ou DC | DC |
Vitesse/Caractéristique | aR |
Taille du fusible | 25G |
Montage | Boulonné |
I2t de fusion | 8190 A²s |
Max. Time to clear MBC | 0.5 s |
Max. Rated Breaking Capacity DC | 30 kA @ 500 V, L/R ≤ 2.5ms |
DC Min. Breaking Capacity (MBC) | 1000 A @ 500 VDC, ≤ 2.5 ms |
DC Total clearing I2t | 70000 A²s |
Connexion / Matériel terminal | Cuivre étamé |
Type de Connexion / Borne | Boulonné |
Diamètre du produit | 25 mm |
Longueur du produit | 92 mm |
Quantité du pack de vente | 12 EA |
Poids du pack de vente | 0.9 kg |
Largeur du pack de vente | 271 mm |
Longueur du pack de vente | 159 mm |
Hauteur du pack de vente | 90 mm |
Groupe de produits | EV and Battery Protection Fuses |
Matériau isolant / corps | GMG |
Poids du produit | 0.075 kg |
Dissipation thermique à la valeur de courant intermédiaire | 4.3 W @ 0.5 In |