Précédent
PHP-MEV100A200-4Y

MEV100A200-4Y - MEV100A200-4Y

EVpack 1000VDC UL 200A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné M8

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.

EVpack 1000VDC UL 200A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné M8

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.

Caractéristiques produit
Numéro d'article MEV100A200-4Y
Numéro de catalogue MEV100A200-4Y
Description EVpack 1000VDC UL 200A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné M8
Code EAN / UPC 0782001491536
Tension nominale DC UL 1000 V
Courant assigné 200 A
Conforme à ROHS Oui
AC ou DC DC
Back to top