5 kV Bolt-On Mount Motor
Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses are single, double, triple or quadruple barrels 3 inches diameter with end mounts designed for bolting directly to equipment bus or terminal pads.
Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses are single, double, triple or quadruple barrels 3 inches diameter with end mounts designed for bolting directly to equipment bus or terminal pads.
Product data sheets
- DS-5kV-Bolt-On-Mount-Motor-Protection-Mersen
pdf - 501.39 KB
Brochures and Flyers
- BR-Ampgard-Brochure-Mersen
pdf - 7.68 MB
Compliance
- COM-RoHS-RS000071-5kV-Bolt-On-Mount-Motor-Mersen
pdf - 141.91 KB
- COM-REACH-RE000071-5kV-Bolt-On-Mount-Motor-Mersen
pdf - 201.21 KB
Key features & benefits
The Amp-Trap Bolt-in series are UL Recognized
Bolt-in mounting for direct connection to bus or terminals
Current-limiting for superior equipment protection
Metal embossed catalog number and manufacturing date for lasting identification
Blown-fuse indicator to give positive identification of open fuse
Amp-Trap: 3" Barrel 2 lb tripped force - 0.50 Inch
Applications
Short circuit protection of medium voltage motors and motor controllers
Frequency (Hz) | 50/60 Hz |
Amperage Range | 2R to 38R |
Speed/Characteristic | R-Rated |
UL Category Code | MSSS2 |
Reach Compliant | Yes |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853510 |
UL File Number | File E93367 |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A051B1DAR0-12R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DAR0-2R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DAR0-3R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DAR0-4R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DAR0-6R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DAR0-9R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DHR0-12R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DHR0-2R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DHR0-3R See product
|
- | - | - | Yes | 5.4431kg |
A051B1DHR0-4R See product
|
- | - | - | Yes | 5.4431kg |