7.2 kV Ferrule Mount Motor
Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses come with a 3 (size D) or 4 (size E) inch diameter barrels with ferrules and are mounted in spring reinforced clips
Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses come with a 3 (size D) or 4 (size E) inch diameter barrels with ferrules and are mounted in spring reinforced clips
Product data sheets
- DS-7.2kV-Ferrule-Mount-Motor-Protection-Mersen
pdf - 295.92 KB
Compliance
- COM-RoHS-RS000076-7.2kV-Ferrule-Mount-Motor-Mersen
pdf - 141.87 KB
- COM-REACH-RE000076-7.2kV-Ferrule-Mount-Motor-Mersen
pdf - 200.31 KB
- COM-REACH-RE000076-7.2kV-Ferrule-Mount-Motor-Mersen
pdf - 200.31 KB
Key features & benefits
The Amp-Trap and 9F60 R-Rated fuses are UL Recognized
Ferrule mounting for standard clips and interchangeability with other brands of fuses
Current-limiting for superior equipment protection
Metal embossed catalog number and manufacturing date for lasting identification
Hookeye for non load-break isolation by hookstick:
On the 4.8kV an optional hookeye mounted in the factory is available
On all other 3" barrels if a hookeye is required, use the operating eye 9F61AAW612
Blown-fuse indicator to give positive identification of open fuse
Amp trap: 3" Barrel 2 lb tripped force - 0.50 Inch
9F60: 0.125 lb tripped force – 0.20 Inch
Applications
Short circuit protection of medium voltage motors and motor controllers
Frequency (Hz) | 50/60 Hz |
Amperage Range | 1R to 36R |
Speed/Characteristic | R-Rated |
UL Category Code | MSSS2 |
Reach Compliant | Yes |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853510 |
UL File Number | File E93367 |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A072F1D0R0-12R See product
|
- | - | - | Yes | 4.9895kg |
A072F1D0R0-2R See product
|
- | - | - | Yes | 4.9895kg |
A072F1D0R0-3R See product
|
- | - | - | Yes | 4.9895kg |
A072F1D0R0-4R See product
|
- | - | - | Yes | 4.9895kg |
A072F1D0R0-5R See product
|
- | - | - | Yes | 4.9895kg |
A072F1D0R0-6R See product
|
- | - | - | Yes | 4.9895kg |
A072F1D0R0-9R See product
|
- | - | - | Yes | 4.9895kg |
A072F2D0R0-18R See product
|
- | - | - | Yes | 9.0718kg |
A072F2D0R0-24R See product
|
- | - | - | Yes | 9.0718kg |