Back
Where to buy Contact us
PHP-A2D-Reducer-Fuses-Photos

A2D-R - Reducer Fuses - Class RK1 - Time-Delay

Approvals & Standards
UL listed to standard 248-12
DC listed to UL standard 248
CSA certified to standard C22.2
No. 248.12

Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 no damage protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace obsolete 250V Class H, K or RK5 fuses already installed in the field.

Amp-Trap 2000 SmartSpot time-delay A2D-R fuses provide IEC Type 2 no damage protection to existing mains, feeders, and branch circuits serving motor and non-motor loads. A2D-R fuses will open fast enough under extreme fault conditions for maximum short circuit protection to prevent damage to motor starters, switches, and other circuit components, yet also provide the time-delay needed for motor in-rush currents. A2D-R fuses can be used to replace obsolete 250V Class H, K or RK5 fuses already installed in the field.

Key features & benefits

  • Replaces traditional temporary-use only Fuse Reducer accessories

  • Time-delay for motor starting and transformer inrush currents

  • without nuisance opening

  • 300kA interrupting rating - self-certified, UL witnessed tests

  • Extremely current-limiting for low peak let-thru current

  • Recommended for Arc Flash energy reduction

  • Easy 2-to-1 selectivity for prevention of nuisance shut downs and

  • “black outs”

  • Rejection-style design prevents replacement errors (when used

  • with recommended fuse blocks)

  • High-visibility orange label gives instant brand recognition

  • Reduced inventory by taking the place of lower-rated Class RK1

  • fuses and associated Fuse Reducer accessories

  • Metal-embossed date and catalog number for easier traceability

  • and lasting identification

  • Fiberglass body provides dimensional stability in harsh industrial

  • settings

Applications

  • Motors

  • Safety switches

  • Transformers

  • Branch circuit protection

  • Disconnects

  • Control panels

  • All general-purpose circuit

Technical Specifications
Frequency (Hz) 50/60 Hz
Amperage Range 110 to 400 A
Fuse Class Class RK1
Speed/Characteristic Time Delay
Flammability Rating 94 V-0

Reference Finder

10 references in this series

Scroll

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
A2D110/400R See product
110A - - Yes 0.8664kg
A2D125/400R See product
125A - - Yes 0.8664kg
A2D150/400R See product
150A - - Yes 0.8664kg
A2D175/400R See product
175A - - Yes 0.8664kg
A2D200/400R See product
200A - - Yes 0.8664kg
A2D225/600R See product
225A - - Yes 1.4061kg
A2D250/600R See product
250A - - Yes 1.4061kg
A2D300/600R See product
300A - - Yes 1.4061kg
A2D350/600R See product
350A - - Yes 1.4061kg
A2D400/600R See product
400A - - Yes 1.4061kg
Back to top