Class J Fuse Holders - Gen2
Mersen’s new Generation 2 open style class J fuse blocks accommodate class J fuses ranging from 0-100A, 600V. A choice of screw, pressure plate, and box connectors fit a wide range of stranded or solid wire. Gen2 fuse blocks are DIN-rail mountable, more compact than the traditional offering, and feature dovetail nesting for multipole field assembly. Fuse bases are IP20 rated when paired with Mersen’s newly designed dead front covers.
Mersen’s new Generation 2 open style class J fuse blocks accommodate class J fuses ranging from 0-100A, 600V. A choice of screw, pressure plate, and box connectors fit a wide range of stranded or solid wire. Gen2 fuse blocks are DIN-rail mountable, more compact than the traditional offering, and feature dovetail nesting for multipole field assembly. Fuse bases are IP20 rated when paired with Mersen’s newly designed dead front covers.
Product data sheets
- DS-Class-J-Fuse-Holders-Gen2-Mersen-EN
pdf - 631.18 KB
Charts
- CHT-Class-J-Fuse Blocks-Gen2-Cross-Reference-Mersen-EN
pdf - 293.1 KB
Compliance
- COM-CE-ROHS-Declaration_Class J_-_Fuse Holders-23-0003
pdf - 176.51 KB
Key features & benefits
DIN-rail mountable, 600V, 30-100A fuse bases
30A is available with box, screw, and pressure plate terminations; 60A & 100A is available with box only
Fresh new Mersen gray color for fuse base
Dovetail design for interlocking configuration of 2-pole and 3-pole bases
Unique molding around the termination to accommodate hinged cover and for increased safety
Built-in lockout/tagout feature
IP20 finger safe
New clear covers with indicators for safety and visual inspections
Multi-connector wiring options
Applications
Branch circuits
Control panels
Load centers
Lighting, heating, & general loads
Technical Specifications
Frequency (Hz) | 50/60 Hz |
Amperage Range | 0 to 100 A |
Fuse Class | Class J |
Short Circuit Current Rating (SCCR) | 200 kA |
Flammability Rating | 94 V-0 |
UL Category Code | IZLT |
CSA File Number | Class 6225, File 032169_0_000 |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853690 |
UL File Number | File E52283 |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Fuse Type/Class | Number of poles | Indication System | Product weight |
---|---|---|---|---|---|---|
FB60J100B1 See product
|
100A | - | Class J | 1-Pole | No | 0.2087kg |
FB60J100B2 See product
|
100A | - | Class J | 2-Pole | No | 0.4173kg |
FB60J100B3 See product
|
100A | - | Class J | 3-Pole | No | 0.6305kg |
FB60J30B1 See product
|
30A | - | Class J | 1-Pole | No | 0.0816kg |
FB60J30B2 See product
|
30A | - | Class J | 2-Pole | No | 0.1588kg |
FB60J30B3 See product
|
30A | - | Class J | 3-Pole | No | 0.2404kg |
FB60J30P1 See product
|
30A | - | Class J | 1-Pole | No | 0.0816kg |
FB60J30P2 See product
|
30A | - | Class J | 2-Pole | No | 0.1588kg |
FB60J30P3 See product
|
30A | - | Class J | 3-Pole | No | 0.2404kg |
FB60J30S1 See product
|
30A | - | Class J | 1-Pole | No | 0.0816kg |