EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.

EVpack Fuse 1000VDC UL 100A Max. Rated Breaking Capacity DC: 20 kA @ 1000 V L/R ≤ 1 ms M8 Bolted

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection. The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.

Technical Specifications
Item number MEV100A100-4Y
Catalogue No MEV100A100-4Y
Description EVpack Fuse 1000VDC UL 100A Max. Rated Breaking Capacity DC: 20 kA @ 1000 V L/R ≤ 1 ms M8 Bolted
EAN/UPC Code 0782001491499
Rated voltage DC UL 1000 V
Ampere Rating 100 A
ROHS Compliant Yes
AC or DC DC