FSPDB5A
FSPDB Series UL 1059 Finger-Safe Power Distribution Block 600V 840A - 840A Tin-plated Aluminum 1-Pole 2 - 2 openings; 600 - #4 --- 600 - #4
FSPDBs introduce a new level of safety and ease for installing power distribution blocks. An IP20 level of finger safe protection is achieved using the FSPDBs and thus eliminates the need for special covers or custom Plexiglas sheets to protect your panels. FSPDBs (sizes 1 to 4) simply snap onto 35mm DIN rail to provide the quickest installation. And since they are modular, you can form any number of poles desired. If multi-pole panel mounting is desired, multiple-pole assembly pins are available. FSPDBs provide a safe, convenient way of splicing cables, splitting primary power into a variety of secondary circuits or providing a fixed junction tap-off point.
FSPDB Series UL 1059 Finger-Safe Power Distribution Block 600V 840A - 840A Tin-plated Aluminum 1-Pole 2 - 2 openings; 600 - #4 --- 600 - #4
FSPDBs introduce a new level of safety and ease for installing power distribution blocks. An IP20 level of finger safe protection is achieved using the FSPDBs and thus eliminates the need for special covers or custom Plexiglas sheets to protect your panels. FSPDBs (sizes 1 to 4) simply snap onto 35mm DIN rail to provide the quickest installation. And since they are modular, you can form any number of poles desired. If multi-pole panel mounting is desired, multiple-pole assembly pins are available. FSPDBs provide a safe, convenient way of splicing cables, splitting primary power into a variety of secondary circuits or providing a fixed junction tap-off point.
Datasheets
Drawings
Item number | FSPDB5A |
Description | FSPDB Series UL 1059 Finger-Safe Power Distribution Block 600V 840A - 840A Tin-plated Aluminum 1-Pole 2 - 2 openings; 600 - #4 --- 600 - #4 |
EAN/UPC Code | 782001319663 |
Rated voltage AC UL | 600 V |
Rated voltage DC UL | 600 V |
Frequency (Hz) | 50/60 Hz |
Ampere Rating (AL) | 840 A |
Ampere Rating (CU) | 840 A |
ROHS Compliant | Yes |
AC or DC | AC/DC |
Short Circuit Rating (Class CC) | 100 kA with 30A Fuse |
Short Circuit Rating (Class G) | 100 kA with 60A Fuse |
Short Circuit Rating (Class J) | 100 kA with 600A Fuse |
Short Circuit Rating (Class L) | Not Tested |
Short Circuit Rating (Class RK1) | 100 kA with 600A Fuse |
Short Circuit Rating (Class RK5) | 100 kA with 400A Fuse |
Short Circuit Rating (Standalone) | 10 kA |
Short Circuit Rating (Class T) | 100 kA with 600A Fuse |
Number of Poles | 1-Pole |
Connector Material | Aluminium étamé |
Number of Openings per Pole (Primary) | 2 |
Number of Openings per Pole (Secondary) | 2 |
Connector Type (Primary) | Box |
Connector Type (Secondary) | Box |
Hole Diameter (Primary) | 0.95 in |
Hole Diameter (Secondary) | 0.95 in |
Torque Rating (Primary) | 600-500 310; 400-2/0 220; 1/0-#2 170; #3-#4 130 |
Torque Rating (Secondary) | 600-500 310; 400-2/0 220; 1/0-#2 170; #3-#4 130; |
Wire Range (Primary) | 600 - #4 |
Wire Range (Secondary) | 600 - #4 |
Installation Mounting | Screw |
Product Width | 72.1 mm |
Product Length | 145 mm |
Product Height | 80 mm |
Sell Pack Quantity | 3 EA |
Sell Pack Weight | 3.8601 kg |
Sell Pack Width | 254 mm |
Sell Pack Length | 158.8 mm |
Sell Pack Height | 88.9 mm |
Product group | Power Distribution Blocks |
Body/Insulating Material | Nylon |
Product Weight | 1.2247 kg |