Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Product
A072B3DBR0-48X
Back-Up R-Rated Medium Voltage Fuse 7200VAC 48X Mounting: Bolted Style: DBRO Visual Indicator Amp-Trap®
Read
Product
A072B3DBR0-57X
Back-Up R-Rated Medium Voltage Fuse 7200VAC 57X Mounting: Bolted Style: DBRO Visual Indicator Amp-Trap®
Read
Product
A072B3DCR0-48X
Back-Up R-Rated Medium Voltage Fuse 7200VAC 48X Mounting: Bolted Style: DCR0 Visual Indicator Amp-Trap®
Read
Product
A072B3DCR0-57X
Back-Up R-Rated Medium Voltage Fuse 7200VAC 57X Mounting: Bolted Style: DCR0 Visual Indicator Amp-Trap®
Read
Series
3.3 kV DIN Mount Motor
Amp-Trap® R-Rated DIN style fuses are current-limiting, high interrupting rating fuses, intended for the short circuit protection of medium voltage motors and motor controllers. This product range offers North American R-Rated performance in the IEC 282-1 DIN mounting configuration of 442mm. R-Rated fuses are applied as back up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. Amp-Trap R-Rated, DIN type fuses are offered in voltage ratings of 3.3kV, 5.3kV and 7.2kV in ratings from 2R to 19R. All fuses within this product group are UL component recognized.
DEFINITIONS:
*R-Rating: R-Rated fuses are back-up fuses that operate as follows (Per ANSI C37.46-2000): An R-Rated fuse will melt in the range of 15 to 35 seconds at a value of current equal to 100 times the “R” rating
*Back-up Current-Limiting Fuses: A back-up current-limiting fuse is a fuse that can interrupt any current between its rated minimum interrupting current and its maximum interrupting current. Back-up fuses are not designed or intended to open under overload conditions
*Continuous Ampere Rating at 40°C: The continuous amp rating defines the thermal capability of the fuse per ANSI C37.46 and should not be the sole factor in fuse selection
*Spring-Reinforced Clip MR45 & Spring Ref.# L096472
*Fuse-Holder: SI 24/442 Ref # K209424 In compliance with IEC 282-1, DIN standard 43625
*Note: Ratings above 19R may be achieved by paralleling fuses. Please consult factory for details
Read
Product
A033D1DSR0-12R
Back-Up R-Rated Medium Voltage Fuse 3.3 kV DIN Mount Motor 12R Visual Indicator
Read
Product
A051B3DAR0-48X
Back-Up R-Rated Medium Voltage Fuse 5080VAC 48X Mounting: Bolted Style: DAR0 Visual Indicator Amp-Trap®
Read
Product
A051B3DAR0-57X
Back-Up R-Rated Medium Voltage Fuse 5080VAC 57X Mounting: Bolted Style: DAR0 Visual Indicator Amp-Trap®
Read
Series
7.2 kV Bolt-On Mount Motor
Mersen R-Rated fuses are current-limiting, high interrupting rating fuses intended for the short circuit protection of medium voltage motors and motor controllers. R-Rated fuses are back-up fuses that have a minimum interrupting rating, and must be coordinated with overload relays in combination motor starters. The motor starter manufacturer generally specifies the R-Rated fuse size. These fuses are single, double, triple or quadruple barrels 3 inches diameter with end mounts designed for bolting directly to equipment bus or terminal pads
Read
Product
A072B1D0R0-19R
Back-Up R-Rated Medium Voltage Fuse 7200VAC 19R Mounting: Bolted Style: D0R0 Visual Indicator Amp-Trap®
Read