K1032962 - 45DB360V32PTS
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 36kVAC IEC 31.5A d65mm, L537mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 36kVAC IEC 31.5A d65mm, L537mm With Thermal Striker 80N Low power losses
Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear and controlgear and high-voltage systems for decades. For the Limitor®-PTS range, Mersen innovates with new fuse-element designs to reduce power losses and new thermal striker to prevent overheating in the fuse compartment of the switch gear. Mersen uses the best materials : fuse-elements are in pure silver, caps are in copper coated with silver and body is in ceramic. Limitor®-PTS HV fuse-links are dedicated to protect transformers in combination with air or gas insulated switchgear against the thermal and dynamic effects of short-circuits. Siemens and Ormazabal recommend Limitor®-PTS HV fuses to be used in their gas-insulated switchgear.
Item number | K1032962 |
Catalogue No | 45DB360V32PTS |
Description | High Voltage DIN Back-up fuse for Transformer Limitor® VDE T402 36kVAC IEC 31.5A d65mm, L537mm With Thermal Striker 80N Low power losses |
EAN/UPC Code | 3605340537789 |
Rated voltage AC IEC | 36 kV |
Ampere Rating | 31.5 A |
AC or DC | AC |
Fuse Size | d=65mm, L=537mm |
Mounting | Clip |
Clearing I2t At Rated Voltage | 7000 A²s |
AC Max I.R./Breaking Capacity: I1 | 20 kA |
Min Interrupting Rating (MBC) | 135 A |
Design Details | VDE T402 |
Indication System | Yes |
Indication System Type | Striker |
Connection/Terminal Material | Silver-Plated Copper |
Connection/Terminal Type | Cylindrical |
Product Diameter | 65 mm |
Product Length | 603 mm |
Sell Pack Quantity | 1 EA |
Sell Pack Weight | 3.8 kg |
Sell Pack Width | 110 mm |
Sell Pack Length | 650 mm |
Sell Pack Height | 100 mm |
Product group | High Voltage IEC Fuses |
Body/Insulating Material | Ceramic |
Product Weight | 3.8 kg |
Power Dissipation at Rated Current Value | 119 W |