Back
Where to buy Contact us
PHP-LABCMB00RST9-MSL
PHP-LABCMB00RST9-MSL

MULTIBLOC® 00.RST9 , Size 00, 160A, 690VAC, Design for bus bar installation, Triple Pole

Approvals & Standards
IEC/EN 60 947-3
For NH fuse-links size 000/00 in accordance with IEC/EN 60269-2, VDE 0636-2

The production programme of MULTIBLOC® 00.RST9 comprises NH fuse switch disconnectors for 160A. Products are designed in triple pole units for direct installation on to 40 mm and 60mm bus bar systems. For installation of MULTIBLOC® NH fuse switch disconnectors of different sizes in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length. MULTIBLOC® size 00 are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, which allows the installation and combination of individual components. MULTIBLOC® offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance.

The production programme of MULTIBLOC® 00.RST9 comprises NH fuse switch disconnectors for 160A. Products are designed in triple pole units for direct installation on to 40 mm and 60mm bus bar systems. For installation of MULTIBLOC® NH fuse switch disconnectors of different sizes in distribution units with central cover, respective covers are used to obtain a uniform profile in height and length. MULTIBLOC® size 00 are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 00: 160A. The system is a modular system, which allows the installation and combination of individual components. MULTIBLOC® offers the user the possibility of fast and easy installation as well as a high degree of security during installation and maintenance.

Key features & benefits

  • Touch protection IP 30

  • Sealing and padlocking device integrated in switch door cover

  • Voltage test through holes in slidable windows directly at contacts or tags of NH-fuse links

  • Suitable for top/bottom cable terminal connections

  • Cable termination: screw, clamp strap, Al-Cu clamp, frame clamp, extendable for V-terminal - optional

  • For 40 and 60mm bus bar systems, snap on installation on 60mm system without tools

  • Universally useable for bus bars with thickness of 5 and 10mm and widths of 12–30mm

  • Installation covering bus bar carrier (max. height 14,5mm) lateral left or right possible

  • Installation depth 95mm

  • Fuse monitoring - optional

  • Indicating switch for switch door position - optional

  • Safe on load connection/disconnection in accordance with IEC 60947-3

Applications

  • House incoming units

  • Meter distribution units

  • Measuring transformer cabinets

  • Transmitting stations for telecommunications

Technical Specifications
Frequency (Hz) 50 ... 60 Hz
Short Circuit Current Rating (SCCR) 80kA@Ue = AC 400 V; Ie = 160 A / 80kA@Ue = AC 500 V; Ie = 160 A / 80kA@Ue = AC 690 V; Ie = 125 A
CE Conformity Yes
Reach Compliant Yes
Degree of Protection (IP) IP 30

Reference Finder

7 references in this series

Scroll

Item number Fuse size Number of poles Product weight
B1022995 - 3.084.100 See product
00 3-Pole 0.96kg
C1022996 - 3.084.200 See product
00 3-Pole 1.46kg
D1022997 - 3.084.300 See product
00 3-Pole 0.88kg
W1022990 - 2.074.000 See product
00 3-Pole 1.06kg
X1022991 - 3.083.000 See product
00 3-Pole 0.88kg
Y1022992 - 3.083.300 See product
00 3-Pole 0.88kg
Z1022993 - 3.084.000 See product
00 3-Pole 0.93kg