MULTIVERT® 800A, 1260A , Double Fuse Switch Disconnector Size 2 and 3
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® double vertical fuse switch disconnectors are for installation on to 185mm bus bar systems. Available designs are MULTIVERT® 800A (2 x 400A and MULTIVERT® 1260A (2x 630A). They are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2:400A and size 3: 630A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® double vertical fuse switch disconnectors are for installation on to 185mm bus bar systems. Available designs are MULTIVERT® 800A (2 x 400A and MULTIVERT® 1260A (2x 630A). They are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2:400A and size 3: 630A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
Product data sheets
Brochures and Flyers
- BR-Panel-Builder-Mersen-EN
pdf - 6.01 MB
- BR-Fuse_Switch_Disconnector-Mersen-EN
pdf - 3.71 MB
Compliance
- COM-CCC-certificate-Multivert2-swicth-disconnectors
pdf - 3.12 MB
- COM-CCC-certificate-Multivert3-switch-disconnectors
pdf - 3.13 MB
Key features & benefits
NH-double vertical fuse switch disconnector size 2, 800 A ( 2 x 400 A)
NH-double vertical fuse switch disconnector size 3, 1260 A ( 2 x 630 A)
For NH-fuse links in accordance with IEC/EN 60 269-2, VDE 0636-2
Installation on to 185mm bus bar system
Suitable for top/bottom cable terminal connections
Triple pole and single pole switching
Multiple cable termination - design with 3 or 4 cables/pole
Safe on load connection/disconnection in accordance with IEC 60947-3
Applications
Transformer substations
Switch boards for industrial applications
Residential and industrial distribution units
Cable distribution cabinets
Frequency (Hz) | 50 ... 60 Hz |
Short Circuit Current Rating (SCCR) | 18kA@Ue=AC500V;Ie=2 x 400A/28kA@Ue=AC500V;Ie=2 x 630A |
CE Conformity | Yes |
Reach Compliant | Yes |
Degree of Protection (IP) | IP20 |
Reference Finder
Scroll
Item number | Fuse size | Number of poles | Product weight |
---|---|---|---|
S1023125 - 1.500.000 See product
|
3 | 2 x 3-Pole | 13.3kg |
T1023126 - 1.500.004 See product
|
3 | 2 x 3-Pole | 13.8kg |
V1023127 - 1.550.000 See product
|
3 | 2 x 3-Pole | 13.3kg |
W1023128 - 1.550.004 See product
|
3 | 2 x 3-Pole | 13.8kg |
W1023266 - 1.400.000 See product
|
2 | 2 x 3-Pole | 11.6kg |
X1023267 - 1.400.004 See product
|
2 | 2 x 3-Pole | 12.12kg |
Y1023268 - 1.450.000 See product
|
2 | 2 x 3-Pole | 11.9kg |
Z1023269 - 1.450.004 See product
|
2 | 2 x 3-Pole | 12.3kg |