MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 800Vac range includes Size 1 Multivert rated at 160A and answers the specific needs of Photovoltaic application for using String inverters rated at 800Vac. Multivert 800Vac are used for installation on to 185mm bus bar systems. MULTIVERT® 800Vac are designed for NH fuse-links in accordance with IEC/EN 60269, VDE 0636, size 1: 160A. The system is a modular system, that allows the installation of the individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 800Vac range includes Size 1 Multivert rated at 160A and answers the specific needs of Photovoltaic application for using String inverters rated at 800Vac. Multivert 800Vac are used for installation on to 185mm bus bar systems. MULTIVERT® 800Vac are designed for NH fuse-links in accordance with IEC/EN 60269, VDE 0636, size 1: 160A. The system is a modular system, that allows the installation of the individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.
Product data sheets
Brochures and Flyers
- BR-Panel-Builder-Mersen-EN
pdf - 6.01 MB
- BR-Helioprotection-Mersen-EN
pdf - 12.47 MB
- BR-Fuse_Switch_Disconnector-Mersen-EN
pdf - 3.71 MB
Compliance
Key features & benefits
Installation on to 185mm bus bar system
Standard design with M 12 screws: M = 35 ±3Nm
Direct installation without drilling with hooked clamps possible
Symmetrical switch - top/bottom cable terminal connection
Touch protection IP 30 with central cover
Varieties of cable termination: bolt, insert nut, V-terminal.
Other terminations on demand
Safe on load connection/disconnection in accordance with IEC 60947-3
Applications
Power distibution and Motor protection
Photovoltaic application: Protection on lines of String inverters rated at 800Vac
Frequency (Hz) | 50 ... 60 Hz |
Short Circuit Current Rating (SCCR) | Ue=AC 800 V; Ie=160 A 10kA |
CE Conformity | Yes |
Reach Compliant | Yes |
Degree of Protection (IP) | IP30 |
Reference Finder
Scroll
Item number | Fuse size | Number of poles | Product weight |
---|---|---|---|
H1069369 - 8.100.000 See product
|
1 | 3-Pole | 4.52kg |
J1069370 - 8.110.000 See product
|
1 | 3-Pole | 4.46kg |
K1069371 - 8.120.000 See product
|
1 | 3-Pole | 4.38kg |
L1069372 - 8.150.000 See product
|
1 | 3-Pole | 4.67kg |
M1069373 - 8.160.000 See product
|
1 | 3-Pole | 4.63kg |
N1069374 - 8.170.000 See product
|
1 | 3-Pole | 4.55kg |