Back
Where to buy Contact us
PHP-7.2kV-8.25kV-Ferr-Trans-Photos

7.2 kV / 8.25kV Ferrule Mount Transformer Fuses

Approvals & Standards
Some UL listed to standard File E143362

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Mersen fuses for the protection of transformers and distribution lines deliver overload and short circuit protection. These current-limiting fuses will melt at current that can be as low as 1.7 times the fuse current ratings up to its maximum interrupting rating. These fuses are designed to withstand the transformer magnetizing inrush current. They have 2" (size C), 3" (size D) and 2x3" (size DD) inch diameter barrels with ferrules and are mounted in spring reinforced clips.

Key features & benefits

  • Amp-Trap CS-3 and 9F62 series are UL listed for compatibility with UL listed equipment

  • Ferrule mounting for standard clips and interchangeability with other brands of fuses

  • Current-limiting for superior equipment protection

  • Non-venting for silent operation

  • Metal embossed catalog number and manufacturing date for lasting identification

  • Outdoor usage for the 9F62 and 9F60 type EJO

  • Blown-fuse indicator to give positive identification of open fuse: Amp-Trap: 2" Barrel 1 lb tripped force - 0.19 Inch; Amp-Trap: 3" Barrel 2 lb tripped force - 0.50 Inch; 9F60/9F62: 0.125 lb tripped force – 0.20 Inch

Applications

  • Protection for 6.9 kV to 8.3 kV transformers or distribution systems.

Technical Specifications
Frequency (Hz) 50/60 Hz
Amperage Range 10 to 200 A
Speed/Characteristic E-Rated
Reach Compliant Yes
Max Operating Temp. 80 °C

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
9F62DCC080 See product
80A - - Yes 3.6287kg
9F62DCC100 See product
100A - - Yes 3.6287kg
9F62DCC125 See product
125A - - Yes 3.6287kg
9F62DCC150 See product
150A - - Yes 3.6287kg
9F62FCC175 See product
175A - - Yes 7.2575kg
9F62FCC200 See product
200A - - Yes 7.2575kg
9F62FCC250 See product
250A - - Yes 7.2575kg
9F62HCC020 See product
20A - - Yes 1.4969kg
9F62HCC025 See product
25A - - Yes 1.4969kg
9F62HCC030 See product
30A - - Yes 1.4969kg
Back to top