MEV50A150-25G - MEV50A150-25G
EVpack Fuse 500VDC UL 500VDC IEC 150A Size 25G Max. Rated Breaking Capacity DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Bolted
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack Fuse 500VDC UL 500VDC IEC 150A Size 25G Max. Rated Breaking Capacity DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Bolted
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Datasheets
Drawings
pdf - 161.24 KB
Compliances
pdf - 157.17 KB
pdf - 194.54 KB
pdf - 157.1 KB
Item number | MEV50A150-25G |
Catalogue No | MEV50A150-25G |
Description | EVpack Fuse 500VDC UL 500VDC IEC 150A Size 25G Max. Rated Breaking Capacity DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Bolted |
EAN/UPC Code | 6972238870202 |
Rated voltage DC UL | 500 V |
Rated voltage DC IEC | 500 V |
Ampere Rating | 150 A |
ROHS Compliant | Yes |
AC or DC | DC |
Speed/Characteristic | aR |
Fuse Size | 25G |
Mounting | Bolted |
Melting I2t | 4610 A²s |
Max. Time to clear MBC | 0.5 s |
Max. Rated Breaking Capacity DC | 30 kA @ 500 V, L/R ≤ 2.5ms |
DC Min. Breaking Capacity (MBC) | 750 A @ 500 VDC, ≤ 2.5 ms |
DC Total clearing I2t | 51000 A²s |
Connection/Terminal Material | Tin-Plated Copper |
Connection/Terminal Type | Bolted |
Product Diameter | 25 mm |
Product Length | 92 mm |
Sell Pack Quantity | 12 EA |
Sell Pack Weight | 0.9 kg |
Sell Pack Width | 271 mm |
Sell Pack Length | 159 mm |
Sell Pack Height | 90 mm |
Product group | EV and Battery Protection Fuses |
Body/Insulating Material | GMG |
Product Weight | 0.075 kg |
Power Dissipation at Intermediate Current Value | 3.1 W @ 0.5 In |