Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Product
V1000081 - NH4GG69V800P-2
DIN NH Standard fuse-link gG Size NH4 690VAC 800A live tags Striker Body width 100 mm
Read
Product
W1000082 - NH4GG50V1000P-2
DIN NH Standard fuse-link gG Size NH4 500VAC 1000A live tags Striker Body width 100 mm
Read
Product
X1000083 - NH4GG50V1250P-2
DIN NH Standard fuse-link gG Size NH4 500VAC 1250A live tags Striker Body width 100 mm
Read
Series
NH fuse-links gG 500VAC , double indicator/isolated gripping-lugs size 000, 00, 0, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Read
Product
M223755 - NH3GG40V630-1
DIN NH Standard fuse-link gG Size NH3 400VAC 630A isolated tags Double indicator Body width 71.9mm
Read
Series
NH fuse-links gG 400VAC , double indicator/live gripping-lugs size 000, 00, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.
Read
Product
T227257 - NH2GG40V35
DIN NH Standard fuse-link gG Size NH2 400VAC 35A live tags Double indicator Body width 40 mm
Read
Series
NH fuse-links gG 500 - 690VAC , with striker size 0, 1, 2, 3, 4
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Read
Product
Y200788 - NH1GG50V224P-2
DIN NH Standard fuse-link gG Size NH1 500VAC 224A live tags Striker Body width 44.60 mm
Read
Product
N215016C - NH000GG50V80-1/3
DIN NH Standard fuse-link gG Size NH000 500VAC 250VDC 80A isolated tags Double quantity 3 Body width 21mm
Read