Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Product
E215537 - NH4GG69V630-8
DIN NH Standard fuse-link gG Size NH4 690VAC 250VDC 630A live tags Top indicator Body width 100 mm
Read
Product
K216554 - NH4GG69V800-8
DIN NH Standard fuse-link gG Size NH4 690VAC 250VDC 800A live tags Top indicator Body width 100 mm
Read
Product
D1030541A - NH32GTR315KVA-1
DIN NH Standard fuse-link gTr Size NH3 400VAC 455A 315KVA isolated tags Center indicator Body width 72.9 mm
Read
Product
E1030542A - NH32GTR400KVA-1
DIN NH Standard fuse-link gTr Size NH3 400VAC 577A 400KVA isolated tags Center indicator Body width 72.9 mm
Read
Series
NH fuse-links gTr 400VAC, middle indicator/live gripping-lugs size 2, 3, 4a
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base, (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.
NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1,3 times nominal current for up to 10 hours. The fuse link operates at 1,5 times nominal transformer current within 2 hours.
Read
Product
J1030500A - NH3GTR50KVA
DIN NH Standard fuse-link gTr Size NH3 400VAC 72A 50KVA live tags Center indicator Body width 50 mm
Read
Product
S1028691 - NH2GTR50KVA
DIN NH Standard fuse-link gTr Size NH2 400VAC 72A 50KVA live tags Center indicator Body width 40 mm
Read
Product
K1030501A - NH3GTR75KVA
DIN NH Standard fuse-link gTr Size NH3 400VAC 108A 75KVA live tags Center indicator Body width 50 mm
Read
Product
T1028692 - NH2GTR75KVA
DIN NH Standard fuse-link gTr Size NH2 400VAC 108A 75KVA live tags Center indicator Body width 40 mm
Read
Series
NH fuse-links gTr 400VAC, middle indicator/isolated gripping-lugs size 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base, (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current, it must be handled by a qualified professional.
NH-fuse links „gTr“ are used for the protection of transformers. The time/current characteristic is especially adapted to that of the protected transformer and implies optimal selectivity to NH-fuse links characteristic gG. The fuses can be loaded with 1,3 times nominal current for up to 10 hours. The fuse link operates at 1,5 times nominal transformer current within 2 hours.
Read