Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Product
V227994 - NH4AM69V1000-8
DIN NH Standard fuse-link aM Size NH4 690VAC 1000A live tags Top indicator Body width 100 mm
Read
Series
NH fuse-links gG 400VAC , double indicator/isolated gripping-lugs size 000, 00, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.
Read
Product
K216692 - NH3AM50V630P-2
DIN NH Standard fuse-link aM Size NH3 500VAC 630A live tags Striker Body width 69mm
Read
Product
Q1000077 - NH4AM69V630P-2
DIN NH Standard fuse-link aM Size NH4 690VAC 630A live tags Striker Body width 100 mm
Read
Product
R1000078 - NH4AM69V800P-2
DIN NH Standard fuse-link aM Size NH4 690VAC 800A live tags Striker Body width 100 mm
Read
Product
Y1000084 - NH4AM69V1000P-2
DIN NH Standard fuse-link aM Size NH4 690VAC 1000A live tags Striker Body width 100 mm
Read
Product
Z1000085 - NH4AM50V1250P-2
DIN NH Standard fuse-link aM Size NH4 500VAC 1250A live tags Striker Body width 100 mm
Read
Series
NH fuse-links aM 500VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
Read
Series
NH fuse-links aM 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of:
* fuse-base (possibly including terminal covers and phase barriers)
* fuse-link with blade contact
* fuse-link replacement device (LV HRC fuse puller)
Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "aM" NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
Read
Product
P233555 - NH4AM50V400-8
DIN NH Standard fuse-link aM Size NH4 500VAC 400A live tags Top indicator Body width 100 mm
Read