Back
Where to buy Contact us
PHP-LABCMV1-MSL

MULTIVERT® 250A , Size 1, 690VAC

Approvals & Standards
IEC/EN 60 947-3
For NH-fuse links size 1 in accordance with IEC/EN 60 269-2, VDE 0636-2

MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 250A are for installation on to 185mm bus bar systems. MULTIVERT® 250A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 1: 250A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.

MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 250A are for installation on to 185mm bus bar systems. MULTIVERT® 250A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 1: 250A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance.

Key features & benefits

  • Installation on to 185mm bus bar system

  • Standard design with M 12 screws: M = 35 ±3Nm

  • Direct installation without drilling with hooked clamps possible

  • Symmetrical switch - top/bottom cable terminal connection

  • Touch protection IP 30 with central cover

  • Varieties of cable termination: bolt, insert nut, V-terminal

  • Integrated measuring transformer (optional) with unchanged installation depth

  • Safe on load connection/disconnection in accordance with IEC 60947-3

Applications

  • Feeder pillars

  • Transformer substations

  • Switch boards for industrial applications

  • Residential and industrial distribution units

  • Cable distribution cabinets

Technical Specifications
Frequency (Hz) 50 ... 60 Hz
Short Circuit Current Rating (SCCR) 120kA@Ue = AC 400 V; Ie = 250 A / 120kA@Ue = AC 500 V; Ie = 250 A / 120kA@Ue = AC 690 V; Ie = 250 A
CE Conformity Yes
Reach Compliant Yes
Degree of Protection (IP) IP30

Reference Finder

19 references in this series

Scroll

Item number Fuse size Number of poles Product weight
H1002186 - 1.100.000 See product
1 3-Pole 4.52kg
H1023185 - 1.170.000 See product
1 3-Pole 4.6kg
J1023163 - 1.110.000 See product
1 3-Pole 4.46kg
K1023164 - 1.120.000 See product
1 3-Pole 4.38kg
K1023187 - 1.170.600 See product
1 3-Pole 4.6kg
L1002189 - 1.150.000 See product
1 3-Pole 4.67kg
L1023165 - 1.100.062 See product
1 3-Pole 4.6kg
M1023166 - 1.100.072 See product
1 3-Pole 5.3kg
M1023189 - 1.170.900 See product
1 3-Pole 5.8kg
N1023167 - 1.100.083 See product
1 3-Pole 4.6kg
Back to top