MULTIVERT® 400A and i-Xtensio 400A, Size 2, 690VAC
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 400A are for installation on to 185mm bus bar systems. MULTIVERT® 400A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2: 400A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance. 2 alternative designs are available for a user-friendly and adaptable installation according to the needs: - The standard design offers a very compact solution with an installation depth of only 123mm, enabling to save space in the Power distribution cabinets - The i-Xtensio design offers a user-friendly mounting solution for current transformers at the back of the Multivert and more standard installation depth of 150mm
MULTIVERT® NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed for installation on to bus bars in triple pole arrangements. MULTIVERT® 400A are for installation on to 185mm bus bar systems. MULTIVERT® 400A are designed for NH fuse-links in accordance with IEC/EN 60269-2, VDE 0636-2, size 2: 400A. The system is a modular system, that allows the installation of individual components. MULTIVERT® offer the user the possibility of fast and easy installation as well as a high degree of protection during installation and maintenance. 2 alternative designs are available for a user-friendly and adaptable installation according to the needs: - The standard design offers a very compact solution with an installation depth of only 123mm, enabling to save space in the Power distribution cabinets - The i-Xtensio design offers a user-friendly mounting solution for current transformers at the back of the Multivert and more standard installation depth of 150mm
Product data sheets
Brochures and Flyers
- BR-Multivert-IXtensio-Mersen-EN
pdf - 4.37 MB
- BR-Panel-Builder-Mersen-EN
pdf - 6.01 MB
- BR-Fuse_Switch_Disconnector-Mersen-EN
pdf - 3.71 MB
Compliance
- COM-OVE-certificate-25214-003-07-MV400-fuse-switch-disconnector
pdf - 327.04 KB
- COM-CB-certificate-IEC-60947-MV400-fuse-switch-disconnector
pdf - 212.67 KB
Key features & benefits
Installation on to 185 mm bus bar system
Standard design with M 12 screws: M = 35 ±3Nm
Direct installation without drilling with hooked clamps possible
Symmetrical switch - top/bottom cable terminal connection
Touch protection IP 30 with central cover
Varieties of cable termination: bolt, insert nut, V-terminal
Integrated measuring transformer (optional) with unchanged installation depth
Safe on load connection/disconnection in accordance with IEC 60947-3
i-Xtensio new range available for increased installation depth of 150mm and for external Current Transformer mounting possibility
Applications
Feeder pillars
Transformer substations
Switch boards for industrial applications
Residential and industrial distribution units
Cable distribution cabinets
Frequency (Hz) | 50 ... 60 Hz |
Short Circuit Current Rating (SCCR) | 120kA@Ue = AC 400 V; Ie = 400 A / 120kA@Ue = AC 500 V; Ie = 400 A / 120kA@Ue = AC 690 V; Ie = 315 A / 100kA@Ue = AC 690 V; Ie = 400 A |
CE Conformity | Yes |
Reach Compliant | Yes |
Degree of Protection (IP) | IP30 |