Back
Where to buy Contact us
PHP-BSFPgG-MSL

BS88 Fusibles piliers d alimentation gG 415 VAC

Approvals & Standards
ASTA 20
EN 60269-2
BS88-2

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

The majority of existing street lighting networks are normally protected by a common Feeder Protection Device (FPD). FDP is based on a simple overcurrent unidirectional technique to protect against faults on the street lighting cables. The Mersen fuse technology ensures safety in street lighting applications by providing better coordination, immediate isolation and ensures fire safety through safe and correct fuse selection.

The Mersen range of Low Voltage Feeder Pillar Fuse Links are designed for the use with wedge type fuse carriers with fixing centres of 82mm and 92mm. There are primarily for use by Electricity Supply Industries in distribution pillars, open type substation boards, heavy duty service cut-outs and underground disconnecting boxes.

Key features & benefits

  • Better coordination

  • Immediate isolation

  • Ensures fire safety

Applications

  • Feeder pillar for street lighting

  • Electricity Supply Industries in distribution pillars

  • Open type substation boards

  • Heavy duty service cut-outs

  • Underground disconnecting boxes

Technical Specifications
Voltage Range 415 VAC
Amperage Range 20-630A
Speed/Characteristic gG
CE Conformity Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
H1003888 - BJU42V020PA See product
20A 110x36 1125A²s No 0.185kg
H1003911 - BJU42V160SA See product
160A 130x36 168000A²s No 0.281kg
H1003934 - BJU42V400SB See product
400A 130x42 720000A²s No 0.316kg
H1003957 - BJU42V630SD See product
630A 130x74 3800000A²s No 0.706kg
J1003889 - BJU42V025PA See product
25A 110x36 1890A²s No 0.185kg
J1003935 - BJU42V450SC See product
450A 130x50 945000A²s No 0.398kg
K1003890 - BJU42V032PA See product
32A 110x36 3000A²s No 0.185kg
L1003891 - BJU42V040PA See product
40A 110x36 5850A²s No 0.185kg
M1003892 - BJU42V050PA See product
50A 110x36 11700A²s No 0.185kg
N1003893 - BJU42V063PA See product
- 110x36 18000A²s No 0.185kg