MEV55C10 - MEV55C10
EVpack Fuse 550VDC UL 10A Max. Rated Breaking Capacity DC: 20 kA @ 550 V L/R ≤ 1 ms Clip
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
EVpack Fuse 550VDC UL 10A Max. Rated Breaking Capacity DC: 20 kA @ 550 V L/R ≤ 1 ms Clip
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications. EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry. The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection. The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.
Datasheets
Drawings
pdf - 118.93 KB
STEP - 119.23 KB
Compliances
pdf - 142.27 KB
pdf - 284.29 KB
pdf - 183.16 KB
Item number | MEV55C10 |
Catalogue No | MEV55C10 |
Description | EVpack Fuse 550VDC UL 10A Max. Rated Breaking Capacity DC: 20 kA @ 550 V L/R ≤ 1 ms Clip |
EAN/UPC Code | 0782001483029 |
Rated voltage DC UL | 550 V |
Ampere Rating | 10 A |
ROHS Compliant | Yes |
AC or DC | DC |
Mounting | Clip |
Min Interrupting Rating (MBC) | 20 A |
Max. Rated Breaking Capacity DC | 20 kA @ 550 V, L/R ≤ 1 ms |
Connection/Terminal Material | Tin-Plated Copper |
Connection/Terminal Type | Clip |
Product Diameter | 10.3 mm |
Product Length | 38 mm |
Sell Pack Quantity | 10 EA |
Sell Pack Weight | 0.075 kg |
Sell Pack Width | 0.9 mm |
Sell Pack Length | 1.6 mm |
Sell Pack Height | 2.1 mm |
Product group | EV and Battery Protection Fuses |
Product Weight | 0.0075 kg |
Power Dissipation at Intermediate Current Value | 0.45 W @ 0.5 In |