Providing the widest range of circuit protection products in the industry means that we offer solutions for everyone from OEMs and panel builders to MROs and electrical contractors either directly or via electrical distributors.
Product
U71008
Fuse Block 750VAC 750VDC 100A 3-Pole Box
Read
Series
9F61 EK-1 Indoor Support
Fuse supports, fuse disconnect switches and accessories from 2.4kV to 38kV
Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors.
Read
Product
9F61AAB201
9F61 EK-1 Indoor Support 2.75 kV 60 kV 2 inch
Read
Product
9F61AAB301
9F61 EK-1 Indoor Support 2.75 kV 60 kV 3 inch
Read
Product
9F61ABB101
9F61 EK-1 Indoor Support 5.5 kV 60 kV 1.6 inch
Read
Product
9F61ABG101
9F61 EK-1 Indoor Support 8.25 kV 95 kV 1.6 inch
Read
Product
9F61AHM201
9F61 EK-1 Indoor Support 25.8 kV 150 kV 2 inch
Read
Product
9F61AHM301
9F61 EK-1 Indoor Support 25.8 kV 150 kV 3 inch
Read
Product
9F61AHM401
9F61 EK-1 Indoor Support 25.8 kV 150 kV 2x3 inch
Read
Series
9F61 EK-3 Indoor Non-Load Disconnect
Fuse supports, fuse disconnect switches and accessories from 2.4kV to 38kV
Fuse supports, non-disconnecting, are used primarily in potential transformer circuits, or where there is some other disconnecting or isolating device in series with the fuse in the circuit. Disconnecting switch devices have the additional feature of serving to isolate the equipment they protect. It should be noted that disconnecting switches are not load-breaking devices, therefore, the circuit must be open prior to the fuse disconnection. Select either a fuse support or a disconnecting switch for each fuse. Fuse supports and disconnecting switches include live parts for both ends. Both fuse supports and fuse disconnect switches can be mounted vertically or horizontally. The type EK are used for indoor installations while the type EKO are used outdoors.
Read