NH fuse-links gG 400VAC , double indicator/live gripping-lugs size 000, 00, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.
The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.
Product data sheets
Brochures and Flyers
- DS-Microswitches-for-NH-fuse-links-size-000-to-3-EN
pdf - 264.6 KB
- DS-NH-Fuse-Handles-EN
pdf - 804.83 KB
- BR-Panel-Builder-Mersen-EN
pdf - 6.01 MB
Compliance
- COM-VDE-approval-40041751-NH000GG40V-fuses
pdf - 254.32 KB
- COM-REACH-declaration-0020-NHGG-400V-fuses
pdf - 244.7 KB
- COM-CE-ROHS-declaration-0020-NHGG-400V-fuses
pdf - 130.62 KB
- COM-VDE-approval-40041779-NH1GG40V-fuses
pdf - 661.56 KB
- COM-VDE-approval-40041861-NH2GG40V-fuses
pdf - 264.67 KB
- COM-VDE-approval-40041752-NH00GG40V-fuses
pdf - 263.76 KB
- COM-VDE-approval-40041833-NH3GG40V-fuses
pdf - 265.97 KB
Key features & benefits
Dimensions according to DIN 43 620 Parts 1 to 4
Non-isolated gripping lugs
Double indicator
Lead free contact blades
0% cadmium
Applications
gG: general purpose cable and line protection
Amperage Range | 2 ... 630 A |
Speed/Characteristic | gG |
CE Conformity | Yes |
Reach Compliant | Yes |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
A223675 - NH000GG40V4 See product
|
4A | NH000 | - | Yes | 0.133kg |
B223676 - NH000GG40V6 See product
|
6A | NH000 | - | Yes | 0.133kg |
C223677 - NH000GG40V10 See product
|
10A | NH000 | - | Yes | 0.133kg |
D223678 - NH000GG40V16 See product
|
16A | NH000 | - | Yes | 0.133kg |
E223679 - NH000GG40V20 See product
|
20A | NH000 | - | Yes | 0.133kg |
E223702 - NH00GG40V125 See product
|
125A | NH00 | - | Yes | 0.2kg |
F223680 - NH000GG40V25 See product
|
25A | NH000 | - | Yes | 0.133kg |
F223703 - NH00GG40V160 See product
|
160A | NH00 | - | Yes | 0.2kg |
F223726 - NH2GG40V80 See product
|
80A | NH2 | - | Yes | 0.42kg |
G223681 - NH000GG40V32 See product
|
32A | NH000 | - | Yes | 0.133kg |