NH fuse-links gG 400VAC , double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Approvals & Standards
VDE 0636 Part 201
IEC 60269-1 and -2

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.

Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.

Rated Power Dissipation values of Mersen NH fuse-links 400VAC are below the maximum values required by standard IEC 60269.

Key features & benefits

  • Dimensions according to DIN 43 620 Parts 1 to 4

  • Non-isolated gripping lugs

  • Double indicator

  • Lead free contact blades

  • 0% cadmium

Applications

  • gG: general purpose cable and line protection

Technical Specifications
Amperage Range 2 ... 630 A
Speed/Characteristic gG
CE Conformity Yes
Reach Compliant Yes

Reference Finder

Item number Ampere rating Fuse size Clearing I2t At Rated Voltage Indication System Product weight
A223675 - NH000GG40V4 See product
4A NH000 - Yes 0.133kg
B223676 - NH000GG40V6 See product
6A NH000 - Yes 0.133kg
C223677 - NH000GG40V10 See product
10A NH000 - Yes 0.133kg
D223678 - NH000GG40V16 See product
16A NH000 - Yes 0.133kg
E223679 - NH000GG40V20 See product
20A NH000 - Yes 0.133kg
E223702 - NH00GG40V125 See product
125A NH00 - Yes 0.2kg
F223680 - NH000GG40V25 See product
25A NH000 - Yes 0.133kg
F223703 - NH00GG40V160 See product
160A NH00 - Yes 0.2kg
F223726 - NH2GG40V80 See product
80A NH2 - Yes 0.42kg
G223681 - NH000GG40V32 See product
32A NH000 - Yes 0.133kg
Back to top