NH fuse-links gG 690VAC , double indicator/live gripping-lugs size 000, 00, 0, 1, 2, 3
The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
The NH system is classified among plug-in fuse systems and is composed of: * fuse-base (possibly including terminal covers and phase barriers) * fuse-link with blade contact * fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional.
Type "gG" NH fuse-links are full range breaking capacity fuse-links and are used to protect cables and equipment. They can interrupt any current surge, from the lowest fusing current up to their breaking capacity, and so can be used alone as protection. They also protect electrical devices and industrial set-ups from the electrodynamic effects of very high short-circuit currents.
Product data sheets
Brochures and Flyers
- DS-Microswitches-for-NH-fuse-links-size-000-to-3-EN
pdf - 264.6 KB
- DS-NH-Fuse-Handles-EN
pdf - 804.83 KB
- BR-Panel-Builder-Mersen-EN
pdf - 6.01 MB
Compliance
- COM-BV-certificate-3924-NH-AM-GG-indicator-fuses
pdf - 575 KB
- COM-LR-certificate-NH-fuses
pdf - 5.47 MB
- COM-REACH-declaration-0022-NHGG-690V-fuses
pdf - 245.26 KB
- COM-CE-ROHS-declaration-0022-NHGG-690V-fuses
pdf - 130.88 KB
- COM-UKCA-declaration-0022-NHGG-690V-fuses
pdf - 111.95 KB
Key features & benefits
Dimensions according to DIN 43 620 parts 1 to 4
Non-isolated gripping lugs
Double indicator
0% cadmium
Applications
gG: general purpose cable and line protection
Amperage Range | 2 ... 500 A |
Speed/Characteristic | gG |
CE Conformity | Yes |
Reach Compliant | Yes |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
W228478 - NH1GG69V25 See product
|
25A | NH1 | - | Yes | 0.27kg |
W228501 - NH2GG69V300 See product
|
300A | NH2 | - | Yes | 0.64kg |
W233262 - NH1GG69V250 See product
|
250A | NH1 | - | Yes | 0.42kg |
X228456 - NH00GG69V40 See product
|
40A | NH00 | - | Yes | 0.2kg |
X228479 - NH1GG69V32 See product
|
32A | NH1 | - | Yes | 0.27kg |
X228502 - NH2GG69V315 See product
|
315A | NH2 | - | Yes | 0.64kg |
Y228457 - NH00GG69V50 See product
|
50A | NH00 | - | Yes | 0.2kg |
Y228480 - NH1GG69V35 See product
|
35A | NH1 | - | Yes | 0.27kg |
Y228503 - NH2GG69V355 See product
|
355A | NH2 | - | Yes | 0.64kg |
Z228458 - NH00GG69V63 See product
|
63A | NH00 | - | Yes | 0.2kg |