TR-R - Class RK5 - Time-Delay
Tri-Onic TR-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TR-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.
Tri-Onic TR-R current-limiting time-delay fuses are engineered for overcurrent protection of motors, transformers, service entrance equipment, feeders and branch-circuits. The time-delay characteristics of the TR-R safely handle harmless starting currents and inrush currents associated with today's motors and transformers.
Product data sheets
- DS-TR-R-TRS-R-Class-RK5-Time-Delay-Mersen
pdf - 279.41 KB
Compliance
- COM-RoHS-RS000042-TR-R-Mersen
pdf - 143.11 KB
- COM-REACH-RE000042-TR-R-Mersen
pdf - 224.98 KB
Key features & benefits
Time-delay
Current-limiting
AC & DC rated
Optional solid state SmartSpot blown fuse indicator
Time-delay for motor start-ups and transformer inrush currents without nuisance opening
Current-limiting for low peak let-thru current
Rejection-style design prevents replacement errors (when used with recommended fuse blocks)
Easy-to-read label for quick brand recognition and replacement
Metal-embossed date and catalog number for traceability and lasting identification
Fiberglass body provides dimensional stability in harsh industrial settings
High-grade silica filler ensures fast arc quenching and high current limitation
Applications
Motor circuits
Mains
Feeders
Branch circuits
Transformers
Service entrance equipment
General-purpose equipment
Frequency (Hz) | 50/60 Hz |
Amperage Range | 1/10 to 600 A |
Fuse Class | Class RK5 |
Speed/Characteristic | Time Delay |
UL Category Code | JDDZ |
CSA File Number | Class 1422-02 Guide 012636_0 |
Reach Compliant | Yes |
Max Operating Temp. | 80 °C |
Max Storage Temp. | 80 °C |
Min Storage Temp. | -25 °C |
Harmonized System | 853610 |
UL File Number | File E2137 |
Reference Finder
Scroll
Item number | Ampere rating | Fuse size | Clearing I2t At Rated Voltage | Indication System | Product weight |
---|---|---|---|---|---|
TR150RID See product
|
150A | - | - | Yes | 0.3411kg |
TR15R See product
|
15A | - | - | No | 0.0168kg |
TR15R-3PK See product
|
15A | - | - | No | 0.0227kg |
TR15RID See product
|
15A | - | - | Yes | 0.0168kg |
TR17-1/2R See product
|
17.5A | - | - | No | 0.0168kg |
TR17-1/2RID See product
|
17.5A | - | - | Yes | 0.0168kg |
TR175R See product
|
175A | - | - | No | 0.3411kg |
TR175RID See product
|
175A | - | - | Yes | 0.3411kg |
TR1R See product
|
1A | - | - | No | 0.0168kg |
TR2-1/2R See product
|
2.5A | - | - | No | 0.0168kg |